7KQI
Antibodies that engage the hemagglutinin receptor-binding site of influenza B viruses
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 24-ID-C |
Synchrotron site | APS |
Beamline | 24-ID-C |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2017-12-03 |
Detector | DECTRIS PILATUS 6M-F |
Wavelength(s) | 0.979 |
Spacegroup name | P 61 2 2 |
Unit cell lengths | 128.100, 128.100, 235.280 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 49.610 | 50.000 | 4.500 |
High resolution limit [Å] | 4.200 | 40.000 | 4.200 |
Rmerge | 0.740 | 0.094 | 6.648 |
Rmeas | 0.760 | 0.098 | 6.800 |
Total number of observations | 182579 | ||
Number of reflections | 8864 | 7 | 1597 |
<I/σ(I)> | 3.51 | 15.58 | 0.61 |
Completeness [%] | 99.8 | 100 | 100 |
Redundancy | 20.598 | 9.429 | 22.595 |
CC(1/2) | 0.992 | 0.999 | 0.240 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7 | 293 | 200 mM sodium citrate pH 7.0, 20% (wt/vol) PEG 3350 |