7KQH
Antibodies that engage the hemagglutinin receptor-binding site of influenza B viruses
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 24-ID-C |
| Synchrotron site | APS |
| Beamline | 24-ID-C |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2016-12-02 |
| Detector | DECTRIS PILATUS 6M-F |
| Wavelength(s) | 0.979 |
| Spacegroup name | P 31 |
| Unit cell lengths | 132.660, 132.660, 93.130 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Data quality characteristics
| Overall | Inner shell | Outer shell | |
| Low resolution limit [Å] | 114.890 | 114.890 | 3.600 |
| High resolution limit [Å] | 3.500 | 50.000 | 3.500 |
| Rmerge | 0.253 | 0.070 | 6.602 |
| Rmeas | 0.276 | 0.076 | 7.218 |
| Total number of observations | 145358 | ||
| Number of reflections | 23115 | 7 | 1897 |
| <I/σ(I)> | 5.3 | 24.05 | 0.25 |
| Completeness [%] | 99.9 | 100 | 99.8 |
| Redundancy | 6.288 | 7.143 | 6.144 |
| CC(1/2) | 0.995 | 0.998 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 293 | 100 mM HEPES pH 7.5, 25% (wt/vol) PEG 3350 |