Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7KKB

Fluoride channel Fluc-Ec2 mutant S81C with bromide

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 21-ID-D
Synchrotron siteAPS
Beamline21-ID-D
Temperature [K]80
Detector technologyPIXEL
Collection date2018-02-28
DetectorDECTRIS EIGER2 X 9M
Wavelength(s)0.91836
Spacegroup nameP 41
Unit cell lengths87.170, 87.170, 142.730
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution46.650 - 2.900
R-factor0.2229
Rwork0.221
R-free0.25860
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)5a43
Data reduction softwareMOSFLM
Data scaling softwareAimless (0.5.27)
Phasing softwarePHASER
Refinement softwarePHENIX (1.17.1_3660)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]46.65046.6503.080
High resolution limit [Å]2.9008.7002.900
Rmerge0.3700.0733.496
Rmeas0.3860.0793.635
Rpim0.1080.0260.992
Total number of observations2958131144449372
Number of reflections236239063785
<I/σ(I)>9.8282.5
Completeness [%]99.999.4100
Redundancy12.512.613
CC(1/2)0.9810.9790.592
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION2980.1M glycine pH 9 36% PEG 600

219869

PDB entries from 2024-05-15