7JQ7
The Phi-28 gp11 DNA packaging Motor
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 21-ID-G |
| Synchrotron site | APS |
| Beamline | 21-ID-G |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2016-08-17 |
| Detector | RAYONIX MX-300 |
| Wavelength(s) | 0.97872 |
| Spacegroup name | P 43 21 2 |
| Unit cell lengths | 112.200, 112.200, 354.200 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 49.689 - 2.895 |
| R-factor | 0.237 |
| Rwork | 0.235 |
| R-free | 0.28370 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 7jq6 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | PHASER (2.7.18) |
| Refinement software | PHENIX (1.13rc2_2986) |
Data quality characteristics
| Overall | Inner shell | Outer shell | |
| Low resolution limit [Å] | 50.000 | 50.000 | 3.050 |
| High resolution limit [Å] | 2.895 | 8.130 | 2.895 |
| Rmerge | 0.167 | 0.047 | 2.200 |
| Rmeas | 0.172 | 0.049 | 2.332 |
| Rpim | 0.041 | 0.012 | 0.761 |
| Number of reflections | 78650 | 2605 | 2285 |
| <I/σ(I)> | 19.2 | 46.7 | 1 |
| Completeness [%] | 99.9 | 99.4 | 99.9 |
| Redundancy | 17.3 | 16.3 | 9.2 |
| CC(1/2) | 0.985 | 0.996 | 0.330 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 8.1 | 292 | 1.0 M trisodium citrate; 0.1 M tris(hydroxymethyl)aminomethane (Tris), pH 8.1 |