Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7JQ6

The Phi-28 gp11 DNA packaging Motor

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 21-ID-F
Synchrotron siteAPS
Beamline21-ID-F
Temperature [K]100
Detector technologyCCD
Collection date2017-10-15
DetectorRAYONIX MX-300
Wavelength(s)0.97872
Spacegroup nameP 32 2 1
Unit cell lengths135.000, 135.000, 276.700
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution49.382 - 2.900
R-factor0.2427
Rwork0.241
R-free0.27410
Structure solution methodSAD
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwareSHELX
Refinement softwarePHENIX (1.13rc2_2986)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0002.850
High resolution limit [Å]2.8002.800
Rmerge0.183
Rpim0.0281.450
Number of reflections822341138
<I/σ(I)>16.90.495
Completeness [%]85.231.8
Redundancy42.712.3
CC(1/2)0.518
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP5.72931.6 M ammonium sulfate, 0.1 M trisodium citrate, pH 5.7

219869

PDB entries from 2024-05-15