Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7JM4

IRF Transcription Factor

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAUSTRALIAN SYNCHROTRON BEAMLINE MX2
Synchrotron siteAustralian Synchrotron
BeamlineMX2
Temperature [K]100
Detector technologyCCD
Collection date2019-04-17
DetectorADSC QUANTUM 210
Wavelength(s)0.9537
Spacegroup nameP 31 2 1
Unit cell lengths117.802, 117.802, 154.579
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution48.440 - 2.950
R-factor0.1859
Rwork0.185
R-free0.20550
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)2irf
RMSD bond length0.003
RMSD bond angle0.621
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwarePHENIX (1.10.1_2155)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]48.4403.055
High resolution limit [Å]2.9502.950
Rmerge0.1051.251
Rmeas0.111
Rpim1.318
Number of reflections266592492
<I/σ(I)>19.23
Completeness [%]99.0100
Redundancy11.1
CC(1/2)0.9990.692
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP29110 % PEG 4000, 0.1 M Na acetate pH 4.6

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon