7IIG
Endothiapepsin crystal D6a from ECBL follow-up screening campaign used for PanDDA ground state calculation
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | BESSY BEAMLINE 14.2 |
| Synchrotron site | BESSY |
| Beamline | 14.2 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2021-09-28 |
| Detector | DECTRIS PILATUS3 2M |
| Wavelength(s) | 0.9184 |
| Spacegroup name | P 1 21 1 |
| Unit cell lengths | 45.410, 73.100, 52.690 |
| Unit cell angles | 90.00, 109.50, 90.00 |
Refinement procedure
| Resolution | 21.880 - 1.010 |
| R-factor | 0.1367 |
| Rwork | 0.137 |
| R-free | 0.14730 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.005 |
| RMSD bond angle | 0.877 |
| Data reduction software | XDS |
| Data scaling software | XDS |
| Phasing software | PHASER |
| Refinement software | PHENIX ((1.17_3644: ???)) |
Data quality characteristics
| Overall | Inner shell | Outer shell | |
| Low resolution limit [Å] | 21.880 | 3.020 | 1.070 |
| High resolution limit [Å] | 1.010 | 2.140 | 1.010 |
| Rmerge | 0.066 | 0.042 | 1.485 |
| Rmeas | 0.075 | 0.047 | 1.705 |
| Total number of observations | 721617 | ||
| Number of reflections | 168762 | 11517 | 26870 |
| <I/σ(I)> | 9.32 | 31.09 | 0.74 |
| Completeness [%] | 99.4 | ||
| CC(1/2) | 0.999 | 0.997 | 0.343 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 4.6 | 293 | 29 % (w/v) PEG 4000, 0.1 M ammonium acetate and 0.1 M sodium acetate, pH 4.6 |