Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7FVE

PanDDA analysis group deposition -- PHIP in complex with Z488932160

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I04-1
Synchrotron siteDiamond
BeamlineI04-1
Temperature [K]100
Detector technologyPIXEL
Collection date2022-09-24
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.92124
Spacegroup nameC 1 2 1
Unit cell lengths81.985, 27.528, 56.419
Unit cell angles90.00, 100.15, 90.00
Refinement procedure
Resolution27.780 - 1.190
R-factor0.1742
Rwork0.173
R-free0.19740
Structure solution methodFOURIER SYNTHESIS
Starting model (for MR)7av9
RMSD bond length0.008
RMSD bond angle1.707
Data reduction softwareXDS
Data scaling softwareAimless (0.7.7)
Phasing softwareREFMAC
Refinement softwareREFMAC (5.8.0267)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]27.77027.7701.210
High resolution limit [Å]1.1906.5201.190
Rmerge0.0470.0990.130
Rmeas0.0510.1110.182
Rpim0.0200.0500.126
Total number of observations1747951503592
Number of reflections33703
<I/σ(I)>31.355.52.8
Completeness [%]84.098.922.9
Redundancy5.25.41.3
CC(1/2)0.9960.9690.976
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP5.627720% PEG 8000, 0.04M potassium phosphate

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon