Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7FVD

PanDDA analysis group deposition -- PHIP in complex with Z1424453050

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I04-1
Synchrotron siteDiamond
BeamlineI04-1
Temperature [K]100
Detector technologyPIXEL
Collection date2022-09-24
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.92124
Spacegroup nameC 1 2 1
Unit cell lengths81.811, 27.139, 56.307
Unit cell angles90.00, 100.04, 90.00
Refinement procedure
Resolution55.440 - 1.360
R-factor0.1827
Rwork0.181
R-free0.20780
Structure solution methodFOURIER SYNTHESIS
Starting model (for MR)7av9
RMSD bond length0.009
RMSD bond angle1.600
Data reduction softwareXDS
Data scaling softwareAimless (0.7.7)
Phasing softwareREFMAC
Refinement softwareREFMAC (5.8.0267)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]55.45055.4501.380
High resolution limit [Å]1.3507.3001.350
Rmerge0.1210.0992.909
Rmeas0.1330.1123.409
Rpim0.0550.0521.723
Total number of observations15553610563682
Number of reflections26228
<I/σ(I)>24.749.24.2
Completeness [%]97.999.777.9
Redundancy5.95.33.6
CC(1/2)0.9870.9750.054
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP5.627720% PEG 8000, 0.04M potassium phosphate

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon