7FFR
Human Serum Albumin_2
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SSRF BEAMLINE BL18U1 |
| Synchrotron site | SSRF |
| Beamline | BL18U1 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2021-07-12 |
| Detector | DECTRIS PILATUS 6M |
| Wavelength(s) | 0.97915 |
| Spacegroup name | P 1 21 1 |
| Unit cell lengths | 57.981, 87.603, 59.619 |
| Unit cell angles | 90.00, 103.08, 90.00 |
Refinement procedure
| Resolution | 19.780 - 2.310 |
| R-factor | 0.2323 |
| Rwork | 0.230 |
| R-free | 0.25910 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 6m4r |
| Refinement software | PHENIX (1.18.2_3874) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 19.780 | 2.400 |
| High resolution limit [Å] | 2.310 | 2.310 |
| Rmerge | 0.065 | 0.463 |
| Number of reflections | 24015 | 2532 |
| <I/σ(I)> | 9.1 | |
| Completeness [%] | 94.4 | |
| Redundancy | 3 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 298 | PEG |