Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7BD5

Notum Fragment 830

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I04-1
Synchrotron siteDiamond
BeamlineI04-1
Temperature [K]100
Detector technologyPIXEL
Collection date2017-02-02
DetectorDECTRIS PILATUS3 S 6M
Wavelength(s)0.9282
Spacegroup nameP 21 21 21
Unit cell lengths60.560, 73.080, 79.070
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution53.670 - 1.690
R-factor0.2025
Rwork0.201
R-free0.23270
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4uz1
Data reduction softwarexia2
Data scaling softwarexia2
Phasing softwareMOLREP
Refinement softwarePHENIX (1.18.2_3874)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]60.5601.720
High resolution limit [Å]1.6901.690
Number of reflections399881966
<I/σ(I)>8.5
Completeness [%]100.0
Redundancy6.4
CC(1/2)0.9970.484
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP296.5 M Ammonium Sulphate 0.1 M Sodium Citrate, pH4.2

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon