Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7BD2

Notum Fragment 810

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I04-1
Synchrotron siteDiamond
BeamlineI04-1
Temperature [K]100
Detector technologyPIXEL
Collection date2017-02-02
DetectorDECTRIS PILATUS3 S 6M
Wavelength(s)0.9282
Spacegroup nameP 21 21 21
Unit cell lengths59.670, 73.880, 78.540
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution39.960 - 1.520
R-factor0.2006
Rwork0.200
R-free0.22100
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4uz1
Data reduction softwarexia2
Data scaling softwarexia2
Phasing softwareMOLREP
Refinement softwarePHENIX (1.18.2_3874)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]39.9601.550
High resolution limit [Å]1.5201.520
Number of reflections540812645
<I/σ(I)>12.7
Completeness [%]100.0
Redundancy6.5
CC(1/2)1.0000.534
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP2961.5 M Ammonium Sulphate 0.1 M Sodium Citrate, pH4.2

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon