7BAF
Crystal structure of PAFB in complex with zinc
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SOLEIL BEAMLINE PROXIMA 2 |
Synchrotron site | SOLEIL |
Beamline | PROXIMA 2 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2019-09-21 |
Detector | DECTRIS EIGER2 X 9M |
Wavelength(s) | 0.98013 |
Spacegroup name | P 31 |
Unit cell lengths | 32.942, 32.942, 42.825 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 28.530 - 1.123 |
R-factor | 0.1818 |
Rwork | 0.182 |
R-free | 0.18520 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 6haj |
RMSD bond length | 0.009 |
RMSD bond angle | 1.070 |
Data reduction software | pointless |
Data scaling software | Aimless (0.7.4) |
Phasing software | PHASER |
Refinement software | BUSTER (2.10.3 (18-SEP-2020)) |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 28.530 | 28.530 | 1.180 |
High resolution limit [Å] | 1.120 | 3.550 | 1.120 |
Rmerge | 0.163 | 0.116 | 1.014 |
Rmeas | 0.172 | 0.122 | 1.095 |
Rpim | 0.055 | 0.038 | 0.405 |
Total number of observations | 186816 | 6205 | 21226 |
Number of reflections | 19859 | 631 | 2894 |
<I/σ(I)> | 10.4 | 23 | 2.6 |
Completeness [%] | 99.9 | 99.9 | 99.5 |
Redundancy | 9.4 | 9.8 | 7.3 |
CC(1/2) | 0.995 | 0.991 | 0.691 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 5.5 | 293.15 | 0.1 M BIS-TRIS pH 5.5, 25 % PEG 3350, 0.2 M NH4CH3COO |