7B2Y

Notum complex with ARUK3003910

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I03
Synchrotron siteDiamond
BeamlineI03
Temperature [K]100
Detector technologyPIXEL
Collection date2020-11-24
DetectorDECTRIS EIGER2 XE 16M
Wavelength(s)0.9763
Spacegroup nameP 21 21 21
Unit cell lengths60.010, 71.540, 78.020
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution39.610 - 1.230
R-factor0.1874
Rwork0.186
R-free0.20760
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)7arg
Data reduction softwarexia2
Data scaling softwarexia2
Phasing softwareMOLREP
Refinement softwarePHENIX (1.18.2_3874)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]52.7301.250
High resolution limit [Å]1.2301.230
Number of reflections979954782
<I/σ(I)>19.9
Completeness [%]100.0
Redundancy39.6
CC(1/2)1.0000.587
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1EVAPORATION2961.5 M Ammonium Sulphate 0.1 M Sodium Citrate

219869