7B07
TgoT_6G12 apo
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SOLEIL BEAMLINE PROXIMA 1 |
Synchrotron site | SOLEIL |
Beamline | PROXIMA 1 |
Temperature [K] | 293 |
Detector technology | PIXEL |
Collection date | 2018-06-20 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 0.972 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 71.890, 110.490, 111.770 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 49.530 - 3.099 |
R-factor | 0.2618 |
Rwork | 0.262 |
R-free | 0.26490 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1tgo |
RMSD bond length | 0.004 |
RMSD bond angle | 0.660 |
Data reduction software | XDS |
Data scaling software | HKL-2000 |
Phasing software | PHENIX |
Refinement software | BUSTER (2.10.3 (20-MAY-2020)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 49.530 | 3.210 |
High resolution limit [Å] | 3.099 | 3.099 |
Rmerge | 0.193 | 2.756 |
Number of reflections | 132742 | 1621 |
<I/σ(I)> | 8.72 | |
Completeness [%] | 99.4 | |
Redundancy | 3.4 | |
CC(1/2) | 0.998 | 0.552 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293 | 10% PEG 20K and 0.1 M MES-NaOH pH 6.5 |