Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

6ZNU

MaeB PTA domain E544R mutant

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I04
Synchrotron siteDiamond
BeamlineI04
Temperature [K]100
Detector technologyPIXEL
Collection date2018-04-23
DetectorDECTRIS PILATUS3 S 6M
Wavelength(s)0.9795
Spacegroup nameC 1 2 1
Unit cell lengths129.090, 182.850, 119.660
Unit cell angles90.00, 117.69, 90.00
Refinement procedure
Resolution56.863 - 2.330
R-factor0.1981
Rwork0.196
R-free0.23570
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1td9
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwarePHENIX (1.14_3260)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]69.2202.500
High resolution limit [Å]2.3302.330
Number of reflections1042315084
<I/σ(I)>12.031.14
Completeness [%]99.7
Redundancy6.7
CC(1/2)0.9900.590
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION7.52890.1M Hepes pH 7.5 0.2M Magnesium Chloride 10% ethylene glycol 15% peg smear medium 5% propan-2-ol

229380

PDB entries from 2024-12-25

PDB statisticsPDBj update infoContact PDBjnumon