6Z8Z

Copper transporter OprC

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I24
Synchrotron siteDiamond
BeamlineI24
Temperature [K]100
Detector technologyPIXEL
Collection date2019-11-23
DetectorDECTRIS PILATUS3 6M
Wavelength(s)1.35131
Spacegroup nameP 2 21 21
Unit cell lengths67.019, 171.225, 198.196
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution67.020 - 2.560
R-factor0.2408
Rwork0.238
R-free0.29490
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)6fok
RMSD bond length0.008
RMSD bond angle1.077
Data reduction softwarexia2
Data scaling softwareAimless
Phasing softwarePHENIX
Refinement softwarePHENIX (1.17.1_3660)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]129.5702.600
High resolution limit [Å]2.5602.560
Rpim0.096
Number of reflections744407325
<I/σ(I)>5.4
Completeness [%]100.0
Redundancy12.25
CC(1/2)0.339
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP5.52930.34 M Ammonium sulfate 0.1 M Sodium citrate 12 -16 % w/v PEG 4000

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon