Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6YN3

Thrombin in complex with 4-hydroxybenzamide (j89)

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsBESSY BEAMLINE 14.1
Synchrotron siteBESSY
Beamline14.1
Temperature [K]100
Detector technologyPIXEL
Collection date2017-04-08
DetectorDECTRIS PILATUS3 6M
Wavelength(s)0.91841
Spacegroup nameC 1 2 1
Unit cell lengths70.773, 71.377, 72.729
Unit cell angles90.00, 100.70, 90.00
Refinement procedure
Resolution38.530 - 1.490
R-factor0.1398
Rwork0.138
R-free0.16660
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)2zgb
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwarePHASER
Refinement softwarePHENIX (1.16_3549)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0001.580
High resolution limit [Å]1.4901.490
Number of reflections572969091
<I/σ(I)>12.1
Completeness [%]98.6
Redundancy3.43.5
CC(1/2)1.0000.810
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP7.527720mM sodium dihydrogen phosphate pH 7.5 350mM NaCl 27% PEG 8000

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon