6Y2X
RING-DTC domains of Deltex 2, Form 2
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | DIAMOND BEAMLINE I04-1 |
Synchrotron site | Diamond |
Beamline | I04-1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2018-02-24 |
Detector | DECTRIS PILATUS3 S 6M |
Wavelength(s) | 0.91587 |
Spacegroup name | C 2 2 21 |
Unit cell lengths | 41.756, 219.585, 120.822 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 60.411 - 1.770 |
R-factor | 0.2437 |
Rwork | 0.242 |
R-free | 0.27410 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 6y22 |
RMSD bond length | 0.006 |
RMSD bond angle | 0.841 |
Data reduction software | DIALS |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | PHENIX (1.10_2142) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 60.430 | 1.820 |
High resolution limit [Å] | 1.770 | 1.770 |
Rmerge | 0.052 | 0.770 |
Rpim | 0.032 | 0.474 |
Number of reflections | 54018 | 3631 |
<I/σ(I)> | 14.4 | 1.8 |
Completeness [%] | 100.0 | 100 |
Redundancy | 6.6 | 6.8 |
CC(1/2) | 0.999 | 0.581 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 7.6 | 292 | Morpheus condition 60 |