6XTD
Rhs1-CT in complex with cognate immunity protein RhsI1
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | DIAMOND BEAMLINE I03 |
| Synchrotron site | Diamond |
| Beamline | I03 |
| Temperature [K] | 100.15 |
| Detector technology | PIXEL |
| Collection date | 2019-08-04 |
| Detector | DECTRIS EIGER X 16M |
| Wavelength(s) | 0.9150 |
| Spacegroup name | P 1 |
| Unit cell lengths | 39.655, 44.108, 46.807 |
| Unit cell angles | 101.20, 96.13, 114.15 |
Refinement procedure
| Resolution | 35.418 - 1.300 |
| Rwork | 0.121 |
| R-free | 0.16520 |
| Structure solution method | SAD |
| RMSD bond length | 0.020 |
| RMSD bond angle | 2.086 |
| Data reduction software | xia2 |
| Data scaling software | Aimless |
| Phasing software | CRANK2 |
| Refinement software | REFMAC (5.8.0257) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 35.418 | 1.320 |
| High resolution limit [Å] | 1.300 | 1.300 |
| Rmerge | 0.063 | 1.222 |
| Number of reflections | 65672 | 3188 |
| <I/σ(I)> | 15.7 | 1.9 |
| Completeness [%] | 96.1 | 93.9 |
| Redundancy | 10.2 | 10.5 |
| CC(1/2) | 1.000 | 0.808 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 5.5 | 293.15 | 0.1M Bis-Tris pH 5.5 25% PEG 3350 |