Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6X3I

NNAS Fc mutant

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsCLSI BEAMLINE 08ID-1
Synchrotron siteCLSI
Beamline08ID-1
Temperature [K]100
Detector technologyCCD
Collection date2014-09-14
DetectorRAYONIX MX-300
Wavelength(s)0.9795
Spacegroup nameC 2 2 21
Unit cell lengths52.091, 142.504, 75.235
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution48.925 - 2.268
R-factor0.1803
Rwork0.178
R-free0.22100
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3ave
RMSD bond length0.015
RMSD bond angle1.059
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHASER
Refinement softwarePHENIX (dev_1839)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]50.00050.0002.350
High resolution limit [Å]2.2684.8902.270
Rmerge0.0890.0520.971
Number of reflections1333614371305
<I/σ(I)>9.2
Completeness [%]99.999.4100
Redundancy7.26.66.8
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP29430% polyethylene glycol 1500

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon