Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6WZM

LY3041658 Fab bound to CXCL8

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 31-ID
Synchrotron siteAPS
Beamline31-ID
Temperature [K]100
Detector technologyCCD
Collection date2011-11-10
DetectorRAYONIX MX-225
Wavelength(s)0.97931
Spacegroup nameP 21 21 21
Unit cell lengths65.012, 103.629, 193.289
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution96.640 - 2.280
R-factor0.189
Rwork0.187
R-free0.22900
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)Internal
RMSD bond length0.010
RMSD bond angle1.140
Data reduction softwareMOSFLM
Data scaling softwareSCALA
Phasing softwarePHASER
Refinement softwareBUSTER (2.11.7)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]193.2902.400
High resolution limit [Å]2.2802.280
Rmerge0.1010.637
Number of reflections603588751
<I/σ(I)>15.8
Completeness [%]99.8
Redundancy7.3
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP29420% PEG 3350, 200mM Magnesium Chloride

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon