Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6WV6

Human VKOR with phenindione

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 24-ID-C
Synchrotron siteAPS
Beamline24-ID-C
Temperature [K]100
Detector technologyPIXEL
Collection date2016-12-06
DetectorDECTRIS PILATUS 6M-F
Wavelength(s)0.9791
Spacegroup nameP 21 21 2
Unit cell lengths155.019, 84.878, 42.558
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution37.300 - 2.700
R-factor0.228
Rwork0.226
R-free0.26780
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)2b3p
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHASER
Refinement softwarePHENIX (1.18_3855)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]50.00050.0002.750
High resolution limit [Å]2.7007.3202.700
Rmerge0.1170.0400.646
Rmeas0.1420.0490.789
Rpim0.0790.0280.446
Total number of observations45677
Number of reflections15647863738
<I/σ(I)>6.8
Completeness [%]97.194.394.4
Redundancy2.92.82.7
CC(1/2)0.9990.730
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1LIPIDIC CUBIC PHASE6.529534% PEG400, 80 mM lithium sulfate, 0.1 M MES, pH 6.5

219869

PDB entries from 2024-05-15