6WN7

Homo sapiens S100A5

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsALS BEAMLINE 5.0.3
Synchrotron siteALS
Beamline5.0.3
Temperature [K]100
Detector technologyCCD
Collection date2018-03-25
DetectorADSC QUANTUM 315r
Wavelength(s)1
Spacegroup nameP 32
Unit cell lengths76.280, 76.280, 84.240
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution26.000 - 1.250
R-factor0.1862
Rwork0.171
R-free0.20600
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4dir
RMSD bond length0.012
RMSD bond angle1.167
Data reduction softwareMOSFLM (1.16_3549)
Data scaling softwareSCALA
Phasing softwarePHASER
Refinement softwarePHENIX (1.16_3549)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]51.9801.320
High resolution limit [Å]1.2501.250
Number of reflections1514374561
<I/σ(I)>16.2
Completeness [%]99.894.6
Redundancy10.68.4
CC(1/2)1.0000.480
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP2770.2 M ammonium sulfate, 20% w/v PEG8000, cryoprotectant: 25% PEG1500

219869