Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

6WMG

Human Sun2 (500-717)

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 24-ID-C
Synchrotron siteAPS
Beamline24-ID-C
Temperature [K]100
Detector technologyPIXEL
Collection date2013-10-12
DetectorDECTRIS PILATUS 6M-F
Wavelength(s)0.9792
Spacegroup nameH 3 2
Unit cell lengths79.192, 79.192, 199.470
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution56.510 - 1.900
R-factor0.1798
Rwork0.175
R-free0.22250
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4dxt
RMSD bond length0.007
RMSD bond angle0.904
Data reduction softwareHKL-2000
Data scaling softwareSCALEPACK
Phasing softwarePHASER
Refinement softwarePHENIX (1.17_3644)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]56.5101.950
High resolution limit [Å]1.9001.900
Rpim0.0420.599
Number of reflections190721319
<I/σ(I)>241.4
Completeness [%]99.097
Redundancy3.73.4
CC(1/2)0.9960.652
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP829114.5% PEG 3350, 0.2M sodium bromide, 0.1M potassium formate

246031

PDB entries from 2025-12-10

PDB statisticsPDBj update infoContact PDBjnumon