6WJU
Fab Fragment of Anti-human LAG3 antibody (4A10)
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 23-ID-D |
| Synchrotron site | APS |
| Beamline | 23-ID-D |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2019-11-05 |
| Detector | DECTRIS PILATUS 6M |
| Wavelength(s) | 0.979 |
| Spacegroup name | I 41 3 2 |
| Unit cell lengths | 258.050, 258.050, 258.050 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 44.260 - 3.100 |
| R-factor | 0.2312 |
| Rwork | 0.228 |
| R-free | 0.28710 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 5e2t |
| RMSD bond length | 0.004 |
| RMSD bond angle | 0.842 |
| Data reduction software | HKL-2000 |
| Data scaling software | Aimless |
| Phasing software | PHASER |
| Refinement software | REFMAC |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 44.260 | 3.310 |
| High resolution limit [Å] | 3.100 | 3.100 |
| Rmerge | 0.170 | 0.590 |
| Rmeas | 0.200 | 0.680 |
| Rpim | 0.090 | 0.330 |
| Number of reflections | 26760 | 4760 |
| <I/σ(I)> | 7 | 2.9 |
| Completeness [%] | 99.9 | 99.9 |
| Redundancy | 7.5 | 7.5 |
| CC(1/2) | 0.800 | 0.360 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 8.5 | 295 | PEG 4000, Lithium sulphate, Tris-HCl |