6WEM
Crimson 0.9
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRL BEAMLINE BL12-2 |
Synchrotron site | SSRL |
Beamline | BL12-2 |
Temperature [K] | 77 |
Detector technology | PIXEL |
Collection date | 2014-05-31 |
Detector | DECTRIS PILATUS3 6M |
Wavelength(s) | 0.9795 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 71.546, 90.046, 129.518 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 40.000 - 2.040 |
Rwork | 0.191 |
R-free | 0.23500 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 3ip2 |
RMSD bond length | 0.015 |
RMSD bond angle | 1.970 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHASER |
Refinement software | REFMAC (5.8.0258) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 40.000 | 2.160 |
High resolution limit [Å] | 2.040 | 2.040 |
Number of reflections | 53213 | 8162 |
<I/σ(I)> | 12.12 | 2.2 |
Completeness [%] | 99.1 | |
Redundancy | 7.05 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 7 | 291 | 0.2 M MgCl2, 0.1 M Bis-Tris HCl pH 6.5, and 25% PEG 3350 |