Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6W0A

Open-gate KcsA soaked in 1 mM BaCl2

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 24-ID-E
Synchrotron siteAPS
Beamline24-ID-E
Temperature [K]98
Detector technologyPIXEL
Collection date2017-02-08
DetectorDECTRIS EIGER X 16M
Wavelength(s)0.9792
Spacegroup nameI 4
Unit cell lengths156.569, 156.569, 73.895
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution50.826 - 3.237
R-factor0.1826
Rwork0.179
R-free0.24150
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1k4c
RMSD bond length0.011
RMSD bond angle1.261
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwarePHENIX (1.14_3260)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.8263.300
High resolution limit [Å]3.2003.200
Rmerge0.180
Number of reflections143392831
<I/σ(I)>8.5
Completeness [%]99.1
Redundancy6
CC(1/2)0.9900.470
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP5.529320 % PEG 400, 50 mM Magnesium Acetate, 50 mM Sodium Acetate, pH 5.5

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon