6VNH
JAK2 JH1 in complex with PN2-123
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 23-ID-B |
Synchrotron site | APS |
Beamline | 23-ID-B |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2019-07-15 |
Detector | DECTRIS PILATUS3 6M |
Wavelength(s) | 1.0332 |
Spacegroup name | P 41 |
Unit cell lengths | 111.651, 111.651, 70.565 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 39.470 - 2.400 |
R-factor | 0.2312 |
Rwork | 0.230 |
R-free | 0.26650 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 2xa4 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHASER |
Refinement software | PHENIX (1.19_4092) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 43.800 | 2.490 |
High resolution limit [Å] | 2.400 | 2.400 |
Rmeas | 0.069 | |
Number of reflections | 66379 | 3374 |
<I/σ(I)> | 10 | |
Completeness [%] | 99.9 | 99.7 |
Redundancy | 2 | |
CC(1/2) | 1.000 | 0.640 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 5.5 | 291 | 0.1 M Bis-Tris pH 5.5, 0.2 M NaCl, 25% PEG 3350 |