Kindlin-3 double deletion mutant short form

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSSRF BEAMLINE BL19U1
Synchrotron siteSSRF
BeamlineBL19U1
Temperature [K]100
Detector technologyPIXEL
Collection date2018-01-02
DetectorDECTRIS PILATUS3 S 6M
Wavelength(s)0.97853
Spacegroup nameP 21 21 21
Unit cell lengths67.502, 131.487, 134.151
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution46.952 - 2.381
R-factor0.2057
Rwork0.203
R-free0.25710
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)5xpy
RMSD bond length0.004
RMSD bond angle0.706
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHASER
Refinement softwarePHENIX (1.12_2829)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0002.490
High resolution limit [Å]2.3812.400
Rmerge0.0470.594
Rmeas0.0500.630
Rpim0.0160.207
Number of reflections480904708
<I/σ(I)>28.1
Completeness [%]99.6
Redundancy9.3
CC(1/2)0.9980.859
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP27711% PEG 3350 and 0.2 M sodium thiocyanate

219869