Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6V5J

Coiled-coil Trimer with Glu:Leu:Ala Triad

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsENRAF-NONIUS FR591
Temperature [K]100
Detector technologyCCD
Collection date2017-08-18
DetectorAPEX II CCD
Wavelength(s)1.5406
Spacegroup nameH 3
Unit cell lengths38.041, 38.041, 104.276
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution19.020 - 1.700
R-factor0.1757
Rwork0.171
R-free0.21560
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)5uxt
Data reduction softwarePROTEUM PLUS
Data scaling softwarePROTEUM PLUS
Phasing softwarePHENIX
Refinement softwarePHENIX (dev_2906)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]34.7701.768
High resolution limit [Å]1.6901.690
Rmerge0.2980.269
Rmeas0.3100.317
Rpim0.8250.901
Number of reflections122901187
<I/σ(I)>20.2
Completeness [%]99.2
Redundancy7.6
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP29840% PEG300, 100 mM sodium phosphate dibasic/citric acid, pH 4.2

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon