6UPP
Radiation Damage Test of PixJ Pb state crystals
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 23-ID-B |
Synchrotron site | APS |
Beamline | 23-ID-B |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2019-06-13 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 1.033 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 41.910, 61.179, 116.643 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 34.575 - 1.560 |
R-factor | 0.1721 |
Rwork | 0.171 |
R-free | 0.20220 |
Structure solution method | FOURIER SYNTHESIS |
Starting model (for MR) | 6p58 |
Data reduction software | DIALS (1.8.2-g5331de77-release) |
Data scaling software | Aimless (0.6.2) |
Phasing software | PHENIX |
Refinement software | PHENIX (1.16) |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 38.840 | 38.840 | 1.600 |
High resolution limit [Å] | 1.560 | 6.980 | 1.560 |
Rmerge | 0.115 | 0.059 | 0.621 |
Rmeas | 0.138 | 0.071 | 0.740 |
Rpim | 0.075 | 0.040 | 0.397 |
Total number of observations | 141510 | 1696 | 10510 |
Number of reflections | 43374 | 569 | 3117 |
<I/σ(I)> | 4.9 | 11.6 | 1.1 |
Completeness [%] | 99.6 | 98.8 | 98.9 |
Redundancy | 3.3 | 3 | 3.4 |
CC(1/2) | 0.988 | 0.986 | 0.755 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | LIQUID DIFFUSION | 7.5 | 298 | '100mM HEPES pH 7.5, 18% PEG 3350, 200mM MgCl' |