6U7F
HCoV-229E RBD Class IV in complex with human APN
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | CLSI BEAMLINE 08ID-1 |
| Synchrotron site | CLSI |
| Beamline | 08ID-1 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2017-01-21 |
| Detector | RAYONIX MX-300 |
| Wavelength(s) | 0.97949 |
| Spacegroup name | P 1 21 1 |
| Unit cell lengths | 99.158, 98.572, 147.778 |
| Unit cell angles | 90.00, 104.42, 90.00 |
Refinement procedure
| Resolution | 49.382 - 2.750 |
| R-factor | 0.1922 |
| Rwork | 0.190 |
| R-free | 0.22510 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 4fyq |
| Data reduction software | XDS |
| Data scaling software | XSCALE |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.16rc1_3535) |
Data quality characteristics
| Overall | Inner shell | Outer shell | |
| Low resolution limit [Å] | 49.382 | 49.382 | 2.820 |
| High resolution limit [Å] | 2.750 | 12.280 | 2.750 |
| Rmerge | 0.068 | 0.024 | 0.448 |
| Rmeas | 0.079 | 0.028 | 0.521 |
| Total number of observations | 273221 | ||
| Number of reflections | 72016 | 840 | 5288 |
| <I/σ(I)> | 16.24 | 38.97 | 3.51 |
| Completeness [%] | 99.8 | 97.9 | 100 |
| Redundancy | 3.794 | 3.562 | 3.846 |
| CC(1/2) | 0.998 | 0.998 | 0.901 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 6.5 | 298 | 9% PEG8000, 1 mM oxidized glutathione, 1 mM reduced glutathione, 5% glycerol, 100 mM MES, pH 6.5 |