Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6TUN

Helicase domain complex

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID29
Synchrotron siteESRF
BeamlineID29
Temperature [K]100
Detector technologyPIXEL
Collection date2014-07-07
DetectorDECTRIS PILATUS3 S 6M
Wavelength(s)1.0064
Spacegroup nameP 21 21 21
Unit cell lengths74.940, 78.350, 92.330
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution46.710 - 2.070
R-factor0.1933
Rwork0.192
R-free0.22730
Structure solution methodSAD
RMSD bond length0.007
RMSD bond angle0.888
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwareREFMAC
Refinement softwarePHENIX ((1.10_2155: ???))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]46.7102.130
High resolution limit [Å]2.0702.070
Rpim0.0380.439
Number of reflections336752591
<I/σ(I)>11.62
Completeness [%]99.6
Redundancy5.4
CC(1/2)0.9990.759
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP8.5293100 mM Tris pH 8.5 25% PEG8000

219869