Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SLS BEAMLINE X06SA |
| Synchrotron site | SLS |
| Beamline | X06SA |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2010-06-30 |
| Detector | MARRESEARCH |
| Wavelength(s) | 1.0 |
| Spacegroup name | H 3 2 |
| Unit cell lengths | 180.780, 180.780, 237.888 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 41.947 - 1.950 |
| Rwork | 0.260 |
| R-free | 0.28360 |
| Structure solution method | FOURIER SYNTHESIS |
| RMSD bond length | 0.016 |
| RMSD bond angle | 1.882 |
| Data reduction software | DENZO |
| Data scaling software | SCALEPACK |
| Phasing software | REFMAC |
| Refinement software | REFMAC (5.8.0258) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 1.980 |
| High resolution limit [Å] | 1.950 | 1.950 |
| Rmerge | 0.057 | 0.486 |
| Number of reflections | 108121 | 5383 |
| <I/σ(I)> | 26.5 | 3.8 |
| Completeness [%] | 99.9 | 100 |
| Redundancy | 6.3 | 6.3 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 298 | Ammonium sulfate/PEG400 |