6TL4
Photosensory module (PAS-GAF-PHY) of Glycine max phyB
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | BESSY BEAMLINE 14.1 |
| Synchrotron site | BESSY |
| Beamline | 14.1 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2019-11-23 |
| Detector | DECTRIS PILATUS 6M |
| Wavelength(s) | 0.9184 |
| Spacegroup name | P 31 2 1 |
| Unit cell lengths | 102.269, 102.269, 222.918 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 47.170 - 2.900 |
| R-factor | 0.2582 |
| Rwork | 0.257 |
| R-free | 0.28240 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 4our |
| RMSD bond length | 0.009 |
| RMSD bond angle | 1.392 |
| Data reduction software | XDS |
| Data scaling software | Aimless |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.17_3644) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 47.170 | 3.060 |
| High resolution limit [Å] | 2.900 | 2.900 |
| Rmerge | 0.238 | 5.838 |
| Rmeas | 0.251 | 6.140 |
| Rpim | 0.077 | 1.893 |
| Number of reflections | 30704 | 4420 |
| <I/σ(I)> | 12.1 | 0.8 |
| Completeness [%] | 99.9 | 99.9 |
| Redundancy | 19.8 | 19.9 |
| CC(1/2) | 0.999 | 0.591 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 6.5 | 283.15 | 200mM MES, 200mM KSCN, 200mM LiCl2, 1% w/v gamma-PGA, 3% w/v PEG3350 |