6TK9
Purine-nucleoside phosphorylase from Thermus thermophilus
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE ID23-1 |
Synchrotron site | ESRF |
Beamline | ID23-1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2019-10-12 |
Detector | DECTRIS EIGER R 1M |
Wavelength(s) | 0.9790 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 89.850, 120.950, 215.470 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 19.980 - 2.500 |
R-factor | 0.2197 |
Rwork | 0.217 |
R-free | 0.26610 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4uc0 |
RMSD bond length | 0.007 |
RMSD bond angle | 1.583 |
Data reduction software | iMOSFLM |
Data scaling software | SCALA |
Phasing software | PHASER |
Refinement software | REFMAC (5.8.0257) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 20.000 | 3.000 |
High resolution limit [Å] | 2.500 | 2.500 |
Rmerge | 0.085 | 0.435 |
Rmeas | 0.491 | |
Number of reflections | 80416 | 33938 |
<I/σ(I)> | 13.32 | |
Completeness [%] | 98.1 | |
Redundancy | 4.35 | |
CC(1/2) | 0.998 | 0.922 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | COUNTER-DIFFUSION | 297 | SA |