6SM1
Wild type immunoglobulin light chain (WT-1)
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE ID30B |
Synchrotron site | ESRF |
Beamline | ID30B |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2016-10-31 |
Detector | DECTRIS PILATUS3 6M |
Wavelength(s) | 0.97625 |
Spacegroup name | P 63 2 2 |
Unit cell lengths | 104.500, 104.500, 55.220 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 15.000 - 1.550 |
R-factor | 0.143 |
Rwork | 0.142 |
R-free | 0.16490 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4nki |
RMSD bond length | 0.007 |
RMSD bond angle | 1.315 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | PHASER |
Refinement software | REFMAC (5.8.0158) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 1.650 |
High resolution limit [Å] | 1.550 | 1.550 |
Rmerge | 0.046 | 0.587 |
Number of reflections | 26220 | 4387 |
<I/σ(I)> | 20.9 | 3.2 |
Completeness [%] | 99.7 | 99.8 |
Redundancy | 6.2 | |
CC(1/2) | 0.999 | 0.868 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 7.5 | 293 | 0.1M HEPES, 0.2 M CaCl2, 28% PEG 400 |