6SC1
THERMOLYSIN IN COMPLEX WITH FRAGMENT J96
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | BESSY BEAMLINE 14.1 |
Synchrotron site | BESSY |
Beamline | 14.1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2016-04-22 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 0.9184 |
Spacegroup name | P 61 2 2 |
Unit cell lengths | 92.797, 92.797, 129.056 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 50.000 - 1.560 |
R-factor | 0.1521 |
Rwork | 0.151 |
R-free | 0.17510 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | NONE |
RMSD bond length | 0.008 |
RMSD bond angle | 0.930 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHASER |
Refinement software | PHENIX (1.16_3549) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 1.650 |
High resolution limit [Å] | 1.560 | 1.560 |
Number of reflections | 47287 | 7457 |
<I/σ(I)> | 23.95 | 4.83 |
Completeness [%] | 99.9 | 99.4 |
Redundancy | 7 | |
CC(1/2) | 0.999 | 0.940 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 291.15 | 50 MM TRIS/HCL, 1.9 M CSCL, 50% DMSO, PH 7.5 |