6RCE
Pmar-Lig_PreS3
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE ID23-1 |
Synchrotron site | ESRF |
Beamline | ID23-1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2018-08-25 |
Detector | DECTRIS PILATUS3 S 6M |
Wavelength(s) | 0.9919 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 67.137, 103.007, 68.581 |
Unit cell angles | 90.00, 91.01, 90.00 |
Refinement procedure
Resolution | 24.261 - 1.946 |
R-factor | 0.2311 |
Rwork | 0.229 |
R-free | 0.27150 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 6rau |
RMSD bond length | 0.016 |
RMSD bond angle | 1.367 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | PHENIX ((1.14_3260: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 69.000 | 2.050 |
High resolution limit [Å] | 1.946 | 1.946 |
Rmerge | 0.074 | 1.946 |
Rpim | 0.061 | 0.622 |
Number of reflections | 57869 | 2893 |
<I/σ(I)> | 10.2 | 1.5 |
Completeness [%] | 89.0 | 39.2 |
Redundancy | 3.4 | |
CC(1/2) | 0.997 | 0.502 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION | 277 | 17-18% PEG 8K, 100 mM ammonium sulfate, 100 mM Bis-Tris pH 5.5 |