Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID23-1
Synchrotron siteESRF
BeamlineID23-1
Temperature [K]100
Detector technologyPIXEL
Collection date2016-02-11
DetectorDECTRIS PILATUS3 6M
Wavelength(s)0.91976
Spacegroup nameP 21 21 21
Unit cell lengths46.552, 71.358, 94.954
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution41.800 - 2.000
R-factor0.196
Rwork0.194
R-free0.23108
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3gpg
RMSD bond length0.009
RMSD bond angle1.304
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwareMOLREP
Refinement softwareREFMAC (5.8.0155)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]41.8002.050
High resolution limit [Å]2.0002.000
Rmerge0.1340.748
Rmeas0.1730.976
Rpim0.1080.619
Number of reflections220336918
<I/σ(I)>7.32.1
Completeness [%]99.899.8
Redundancy4.54.3
CC(1/2)0.9890.603
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION62930,2M Imidazole Malate pH6 30% PEG 4K