6QWV

SARM1 SAM1-2 domains

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID23-1
Synchrotron siteESRF
BeamlineID23-1
Temperature [K]100
Detector technologyPIXEL
Collection date2018-09-02
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.9795
Spacegroup nameP 43
Unit cell lengths252.246, 252.246, 49.766
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution56.400 - 2.470
R-factor0.1897
Rwork0.189
R-free0.22969
Structure solution methodSAD
RMSD bond length0.007
RMSD bond angle1.457
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwareCRANK2
Refinement softwareREFMAC (5.8.0238)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]56.4002.510
High resolution limit [Å]2.4702.470
Number of reflections113145
<I/σ(I)>7.8
Completeness [%]99.4
Redundancy4.5
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION2932% Tacsimate pH=7, 5% v/v 2-Propanol, 0.1 M Imidazole pH=7, 8% w/v polyethylene glycol 3350

229380