6QUI
GHK tagged GFP variant at 17Kev
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X10SA |
Synchrotron site | SLS |
Beamline | X10SA |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2018-03-18 |
Detector | DECTRIS PILATUS3 6M |
Wavelength(s) | 0.72931 |
Spacegroup name | P 65 2 2 |
Unit cell lengths | 86.252, 86.252, 269.535 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 44.960 - 1.940 |
R-factor | 0.2019 |
Rwork | 0.201 |
R-free | 0.22400 |
Structure solution method | SAD |
RMSD bond length | 0.007 |
RMSD bond angle | 1.402 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | CRANK2 |
Refinement software | REFMAC (5.8.0253) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 44.960 | 1.980 |
High resolution limit [Å] | 1.940 | 1.940 |
Rpim | 0.012 | 0.230 |
Number of reflections | 45055 | 4402 |
<I/σ(I)> | 32.4 | |
Completeness [%] | 100.0 | |
Redundancy | 155.6 | |
CC(1/2) | 1.000 | 0.886 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293 | 0.1M Mes pH 6.5, 1.2M Ammonium sulphate, 8% glycerol |