6QRQ

Apo conformation of chemotaxis sensor ODP

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsCHESS BEAMLINE A1
Synchrotron siteCHESS
BeamlineA1
Temperature [K]100
Detector technologyCCD
Collection date2014-11-12
DetectorADSC QUANTUM 210
Wavelength(s)1.2800
Spacegroup nameP 21 21 21
Unit cell lengths84.650, 110.725, 110.964
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution49.540 - 2.562
Rwork0.191
R-free0.25450
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHASER
Refinement softwarePHENIX
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]49.5402.654
High resolution limit [Å]2.5622.562
Rmerge0.162
Rmeas0.124
Rpim0.050
Number of reflections33480
<I/σ(I)>7.6
Completeness [%]94.0
Redundancy11.6
CC(1/2)0.9970.714
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP2940.1 M Hepes pH 7.5, 7% Isopropanol, 23% polyethyleneglycol 4000