6QQK
Room temperature structure of blue light-irradiated AtPhot2LOV2 recorded after an accumulated dose of 34 kGy
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | ESRF BEAMLINE MASSIF-3 |
| Synchrotron site | ESRF |
| Beamline | MASSIF-3 |
| Temperature [K] | 293 |
| Detector technology | PIXEL |
| Collection date | 2018-06-22 |
| Detector | DECTRIS EIGER R 4M |
| Wavelength(s) | 0.968 |
| Spacegroup name | P 43 21 2 |
| Unit cell lengths | 41.450, 41.450, 133.530 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 39.590 - 2.400 |
| R-factor | 0.24184 |
| Rwork | 0.239 |
| R-free | 0.28623 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 4eep |
| RMSD bond length | 0.002 |
| RMSD bond angle | 1.474 |
| Data reduction software | XDS |
| Data scaling software | XSCALE |
| Phasing software | PHASER |
| Refinement software | REFMAC (5.8.0238) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 39.590 | 2.500 |
| High resolution limit [Å] | 2.400 | 2.400 |
| Number of reflections | 4926 | 558 |
| <I/σ(I)> | 17.64 | 1.52 |
| Completeness [%] | 98.0 | 99.1 |
| Redundancy | 23.1 | 23.5 |
| CC(1/2) | 0.999 | 0.726 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 6 | 293 | 12-17% PEG8000 0.2 M Calcium acetate 0.1 M MES |