6QCG
PCNA complex with Cdt1 N-terminal PIP-box peptide
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | ESRF BEAMLINE ID29 |
| Synchrotron site | ESRF |
| Beamline | ID29 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2014-04-01 |
| Detector | DECTRIS PILATUS 2M |
| Wavelength(s) | 1.0003 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 76.585, 143.173, 173.592 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 46.210 - 3.400 |
| R-factor | 0.20826 |
| Rwork | 0.206 |
| R-free | 0.25308 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.009 |
| RMSD bond angle | 1.702 |
| Data reduction software | XDS |
| Data scaling software | Aimless |
| Phasing software | MOLREP |
| Refinement software | REFMAC (5.8.0238) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 47.720 | 3.630 |
| High resolution limit [Å] | 3.400 | 3.400 |
| Number of reflections | 26813 | |
| <I/σ(I)> | 7.6 | 1.9 |
| Completeness [%] | 99.3 | 99.2 |
| Redundancy | 3.4 | |
| CC(1/2) | 0.647 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 6 | 300 | 15% (w/v) PEG 400, 100 mM calcium acetate, 100 mM MES/HCl |