6Q8F

Nterminal domain of human SMU1

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE BM14
Synchrotron siteESRF
BeamlineBM14
Temperature [K]100
Detector technologyCCD
Collection date2014-09-10
DetectorMARMOSAIC 225 mm CCD
Wavelength(s)0.95373
Spacegroup nameP 1 21 1
Unit cell lengths40.183, 41.225, 123.599
Unit cell angles90.00, 91.48, 90.00
Refinement procedure
Resolution39.140 - 1.900
R-factor0.17644
Rwork0.174
R-free0.21375
Structure solution methodMAD
RMSD bond length0.007
RMSD bond angle1.490
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwareSHELXS
Refinement softwareREFMAC (5.8.0232)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]40.0001.950
High resolution limit [Å]1.9001.900
Rmeas0.0640.536
Number of reflections314231956
<I/σ(I)>22.32.36
Completeness [%]97.281.5
Redundancy5.63.3
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP5.52930.1 M Bis-Tris pH 5.5, 16-20 % PEG 10K, 0.1 M ammonium acetate

219869