6Q4F
CDK2 in complex with FragLite32
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | DIAMOND BEAMLINE I04 |
| Synchrotron site | Diamond |
| Beamline | I04 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2018-02-19 |
| Detector | DECTRIS PILATUS 6M |
| Wavelength(s) | 0.98 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 53.187, 71.467, 72.042 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 50.790 - 1.210 |
| R-factor | 0.16914 |
| Rwork | 0.167 |
| R-free | 0.20515 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 1hck |
| RMSD bond length | 0.015 |
| RMSD bond angle | 1.996 |
| Data reduction software | xia2 |
| Data scaling software | Aimless |
| Phasing software | PHASER |
| Refinement software | REFMAC (5.8.0238) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 72.040 | 1.230 |
| High resolution limit [Å] | 1.210 | 1.210 |
| Rmerge | 0.040 | 0.680 |
| Number of reflections | 84174 | 4137 |
| <I/σ(I)> | 15.3 | 1 |
| Completeness [%] | 99.9 | 97.7 |
| Redundancy | 6.6 | 3.7 |
| CC(1/2) | 0.990 | 0.310 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 7.4 | 293 | 10MG/ML CDK2 10% V/V PEG3350, 50 MM HEPES/NAOH, 50 MM NA/K PHOSPHATE, PH 7.5 |