6Q18
Human antibody H1244 in complex with the influenza hemagglutinin head domain of A/Beijing/262/95(H1N1)
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | ALS BEAMLINE 8.2.2 |
| Synchrotron site | ALS |
| Beamline | 8.2.2 |
| Temperature [K] | 80 |
| Detector technology | CCD |
| Collection date | 2017-10-13 |
| Detector | ADSC QUANTUM 315r |
| Wavelength(s) | 0.9999 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 58.000, 69.640, 191.490 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 49.608 - 2.550 |
| R-factor | 0.2077 |
| Rwork | 0.206 |
| R-free | 0.24320 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Data reduction software | XDS |
| Data scaling software | XSCALE |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.14_3260) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 49.608 | 2.641 |
| High resolution limit [Å] | 2.550 | 2.550 |
| Rmerge | 0.112 | 1.009 |
| Number of reflections | 26099 | 2560 |
| <I/σ(I)> | 17.05 | |
| Completeness [%] | 99.9 | 99.88 |
| Redundancy | 8 | |
| CC(1/2) | 0.998 | 0.883 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 291.15 | 200mM sodium chloride, 30% (v/v) PEG400, 100mM HEPES |