Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6PPM

Ancestral Caspase 6

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 17-BM
Synchrotron siteAPS
Beamline17-BM
Temperature [K]100
Detector technologyCCD
Collection date2019-06-19
DetectorMAR CCD 165 mm
Wavelength(s)1.0
Spacegroup nameP 21 21 21
Unit cell lengths84.314, 88.542, 141.026
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution42.240 - 2.610
R-factor0.182
Rwork0.177
R-free0.25090
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)2j30
RMSD bond length0.007
RMSD bond angle0.911
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHENIX
Refinement softwarePHENIX (1.15.2_3472)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]42.2402.700
High resolution limit [Å]2.6102.610
Number of reflections327243134
<I/σ(I)>5.1
Completeness [%]99.7
Redundancy3.7
CC(1/2)0.951
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP2770.2 M ammonium fluoride, pH 6.2, 20% PEG 3350

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon